AUTHORS: Shelly Vadhera
Download as PDF
ABSTRACT: In this paper the data is collected for eighteen induction machines of different ratings in order to facilitate the study of magnetization characteristics in particular and for design considerations of induction generators in general. The analysis of data as per proposal explained helps to decide the specific limits/bounds of machine parameters. Further this paper highlights the ease with which fuzzy logic can facilitate the designer for judicial selection of machine parameters for efficiency improvements.
KEYWORDS: efficiency, fuzzy logic, machine parameters, magnetization characteristics, induction generator
REFERENCES:
[1] G. Singaravelu and G. Balasubramanian, “ Dynamic and steady-state analysis of selfexcited single-phase two-winding induction generators,” Int. J. of Computer Applications, vol. 53, no. 12, pp. 39-44, Sept. 2012.
[2] M. Senthilkumar, “Optimal capacitor for maximum output power tracking of self excited induction generator using fuzzy logic approach,” Int. J. on Computer Science and Engineering, vol. 2, no. 5, pp. 1758-1762, 2010.
[3] M. S. Kumar, N. Kumaresan, and M. Subbiah, “Performance evaluation of self excited induction generator using fuzzy logic,” IICPE India International Conference on Power Electronics, pp.1-6, 28-30 Jan. 2011.
[4] X. Alabern, “Optimized design of an induction motor using fuzzy logic as a calculus and decision tool” IEMDC’03 International Conference on Electric machines and Drives, pp.83-87, 1-4 June 2003.
[5] E. Adzic, Z. Ivanovic, M.Adzic, and V. Katic, “Optimum fuzzy logic control of induction generator in wind turbine application,” SISY 6th International Symposium on Intelligent Systems and Informatics, pp.1-5, 26-27 Sept. 2008.
[6] H. F. Soliman, A. A. Attia, S. M. Mokhymar, and M. A. L. Badr, “Fuzzy algorithm for supervisory contol of self-excited induction generator,” JKAU: Eng. Sci., vol. 17, no. 2, pp. 19-40, 2006.
[7] H. H. Lee, P. Q. Dzung, L. M. Phuong, L. D. Khoa, and N. H. Nhan, “A new fuzzy logic approach for control of wind turbine with doubly fed induction generator,” IFOST International Forum on Strategic Technology, pp.134-139, 13-15 Oct. 2010.
[8] H. Karimi-Davijani, A. Sheikholeslami, H. Livani, and M. Karimi-Davijani, “Fuzzy logic control of doubly fed induction generator wind turbine,” World Applied Sciences Journal, vol. 6, no. 4, pp. 499-508, 2009.
[9] N. Albert Singh, K.A. Muraleedharan, and K.Gomathy, “An intelligent neuro-fuzzy logic controller for induction generator based wind generation to improve power system stability,” Int. J. of Modelling, Identification and Control, vol. 6, no. 3, pp. 188-195, 2009.
[10] R. B. Mishra, Artificial Intelligence, PHI Learning Pvt. Ltd. New Delhi 2011.
[11] John Yen and Reza Langari, Fuzzy Logic: Intelligence, Control, and Information, Pearson Education Inc. 1999.
[12] R. J. Harrington and F. M. M. Bassiouny, “New approach to determine the critical capacitance for self-excited induction generators,” IEEE Trans. Energy Conversion, vol. 13, no. 3, pp. 244-249, Sep. 1998.
[13] N. H. Malik and S. E. Haque, “Steady state analysis and performance of an isolated selfexcited induction generator,” IEEE Trans. Energy Conversion, vol. 1, no. 3, pp. 134-140, Sep. 1986.
[14] S. S. Murthy, B. P. Singh, C. Nagamani, and K. V. V. Satyanarayana, “Studies on the use of conventional induction motors as self-excited induction generators,” IEEE Trans. Energy Conversion, vol. 3, no. 4, pp. 842-848, Dec. 1988.
[15] S. P. Singh, B. Singh, and M. P. Jain, “Comparative study on the performance of a commercially designed induction generator with induction motors operating as self excited induction generators,” IEE Proc. Pt. C, Generation, Transmission and Distribution, vol. 140, no. 5, pp. 374-380, Sep. 1993.
[16] A. K. Tiwari, S. S. Murthy, B. Singh, and L. Shridhar, “ Design-based performance evaluation of two-winding capacitor selfexcited single-phase induction generator,” Electric Power Systems Research, vol. 67, no. 2, pp. 89-97, Nov. 2003.
[17] T. F. Chan, K. Nigim, and L. L. Lai, “Voltage and frequency control of self-excited slip-ring induction generators,” IEEE Trans. Energy Conversion, vol. 19, no. 1, pp. 81-87, March 2004.
[18] B. Singh, L. Shridhar, and C. S. Jha, “Improvements in the performance of self excited induction generator through series compensation,” IEE Proc. Pt. C, Generation, Transmission and Distribution, vol. 146, no. 6, pp. 602-608, Nov. 1999.
[19] L. A. C. Lopesl and R. G. Almeida, “Wind – driven self-excited induction generator with voltage and frequency regulated by a reducedrating voltage source inverter,” IEEE Trans. Energy Conversion, vol. 21, no. 2, pp. 297-304, June 2006.
[20] G. Raina and O. P. Malik, “Wind energy conversion using a self-excited induction generator,” IEEE Trans. Power Apparatus and Systems, vol. 102, no. 12, pp. 3933-3936, Dec. 1983.
[21] M. Orabi, T. Ahmed, M. Nakaoka, and M. Z. Youssef, “Efficient performance of induction generator for wind energy utilization,” 30th Annual Conference IEEE Industrial Electronics Society, Busan, Korea, pp. 838-843, 2-6 Nov. 2004.
[22] R. S. Khela, R. K. Bansal, K. S. Sandhu, and A. K. Goel, “Cascaded ANN for evaluation of frequency and air gap voltage of self-excited induction generator,” World Academy of Science, Engineering and Technology, vol. 27, pp. 301-307, Oct. 2007.
[23] T. F. Chan and L. L. Lai, “A novel single-phase self-regulated self-excited induction generator using a three-phase machine,” IEEE Trans. Energy Conversion, vol. 16, no. 2, pp. 204-208, June 2001.
[24] T. Fukami, Y. Kaburaki, S. Kawahara, and T. Miyamoto, “Performance analysis of a selfregulated self-excited induction generator using a three-phase machine,” IEEE Trans. Energy Conversion, vol. 14, no. 3, pp.622-627, Sep. 1999.
[25] L. Wang and C. H. Lee, “Dynamic analysis of parallel operated self-excited induction generators feeding an induction motor load,” IEEE Trans. Energy Conversion, vol. 14, no. 3, pp. 479-485, Sep. 1999.
[26] K.S. Sandhu and D Joshi, “Steady sate analysis of self-excited induction generator using phasor-diagram based iterative model,” WSEAS Transactions on Power Systems, vol. 3 no. 12, pp. 715-724, Dec. 2008.